- No switch cabinet needed
- Less cabling on site
- Direct serial communication with host system through various optional protocols.
SCM2 – FIELD
Categories
All Dosing granular Flow measurement granular Dosing powder Flow measurement powder Light materials Controllers & electronic Static weighing Calibration chain
Hasler® controller
The SCM2 is used for any type of HASLER® feeders
The SCM2 (Smart Control Module) is a single feeder control module to acquire and process feeder input data, command signals and to pilot the motor drive unit.
Need more information ?
Feeder and Control Module - All in one
Configuration and maintenance software allowing
- Read & Write of parameters
- Configure remote Inputs / Outputs
- Diagnostics (data acquisition, trend graphic recorder, etc.)
- Remote maintenance
Communication with the Host Sytem
- Modbus TCP (Ethernet)
- Modbus RTU (RS422)
- Allen Bradley Data Highway (RS422)
- Siemens 3964R (RS422)
- Profibus DP (RS485)
- Device-Net
- Modbus Plus
Examples of mounting
Cell connections
Digital load-cell
Analog load-cellAnalog strain-gauge laod cell (through converter) in 4 or 6 wires (up to 65 000 points resolution)
Digital load-cell (1 million de points) i.e. SFT.
In any case, fast weight acquisition and adjustable digital filter allows to compensate structural vibrations
Technical data
Software application | WBF | SFM | LWF | ||||
---|---|---|---|---|---|---|---|
![]() GRAVIT | ![]() MAMMUTHUS | ![]() POWDRIT | ![]() FLOWRIT | ![]() FLOW | ![]() GRAN | ![]() RBP / TVR |
|
Massflow measurement | |||||||
Massflow PID regulation | |||||||
Prefeeding PID regulation | |||||||
Proportioning valve control | |||||||
Belt control (drift, slippage…) | |||||||
Segmented belt taring | |||||||
Periodic taring with by-pass function | |||||||
Feeding gates control | |||||||
Associated weighing hopper | |||||||
On line calibration | |||||||
Hopper feeding regulation | |||||||
Weighing under inlet hopper | |||||||
Continuous level measure in settling chamber for prefeeding regulation | |||||||
Density measurement for prefeeding correction | |||||||
Segmented memorization of volumetric throughput (feed factor) | |||||||
Advanced fluidization of storage silo |
Power requirements
- Supply voltage : 115 VAC ±10% or 230 VAC ±10%
- Supply frequency : 47 - 63 Hz
- Max. Power Consumption : 50 W
- Switch-On Current : Max. 2A for 2AC for 1 or 2 power cycles
Environmental ratings
- Area Classification : General Purpose
- Operating Ambient Temp. : -20°C to 60°C
- Storage Ambient Temp : -25°C to 70°C
- Operating Altitude : <3000m
- Max. Humidity : 95% at 25°C without condensation (DIN 4004to 0 Class F)
- Degree of Protection : IP65
Dimensions of SCM-F®
- Height : 320 mm
- Width : 316 mm
- Depth : 123 mm
Dimensions of the SCM Display (SDU®)
- Height : 140 mm
- Width : 144 mm
- Depth : 60 mm
Dedicated Inputs / Outputs
- Digital Inputs (standard) (i.e., 24VDC...) : 8
- Digital Outputs : 4
- Digital Inputs for speed and index acquisition : 3
- Analog Input : 1
- Analog Output : 1
Remote Inputs / Outputs
- Digital Inputs : 5-24-48 VDC / 24-120-230 VAC
- Digital Outputs : 5-24 VDC / 230 VAC / Relai SPST-DPDT
- Analog Inputs / Outputs : 0-20 mA / 4-20 mA / 0-10 V
Electrical Standards
- General electrical emissions : EN 50081-2
- General Electrical Immunity : EN 50082-2
- Electrical safety : EN 61010-1
Alternative
The SCM2 is also available in a feeder integrated version : PANEL